# How much upper airway volume varies between people

> Upper airway volume on CBCT varies with the person, the group studied and how the airway is outlined, so a published average is not a cut-off.

- URL: https://jawviewer.com/blog/upper-airway-volume-normal-values-variation
- Category: Airway and sinuses
- Published: 2026-11-21
- Updated: 2026-11-21
- Author: Jaw Viewer
- Reading time: 4 min
- Tags: cbct, airway, measurements

## Key points

- A 2023 study of 56 young Japanese adults with normal occlusion reported airway reference data by sex, and found a sex difference in hypopharynx length but not in volume.
- That study measured the oropharynx and hypopharynx only, in one age group and one population, so its numbers do not transfer to other groups.
- A 2010 study of 30 CBCT scans found three DICOM viewers highly repeatable but significantly different from a manual outline, so volumes from different programs are not interchangeable.
- A 2011 review of 46 articles lists breathing phase, tongue position, jaw shape and the definition of airway boundaries as open problems for airway analysis on CBCT.

Upper airway volume varies between people, and published reference numbers apply only to the group and the method behind them. A 2023 study of 56 young Japanese adults found no sex difference in volume, yet a difference in the length of one section of the airway. An average from one study cannot serve as a cut-off for an individual scan.

## What does a published reference value stand for?

A reference value is a description of a sample. One recent example measured 56 young Japanese adults, picked out of 1000 patients so that they matched an older cephalometric group with normal occlusion. The authors built 3D reconstructions of the oropharynx and the hypopharynx from CBCT scans, calculated their volumes, placed 20 landmarks on the surface of each reconstruction and took seven linear measurements between them. They report the mean and standard deviation for each sex.[1]

Each choice in that design narrows what the numbers can say. The people were young, from one population, and chosen for a particular bite. The region excluded the nasal side of the airway. The study states its aim as establishing reference data for that group.[1] It does not claim the figures describe everyone, and this article does not print them, because a number taken out of that setting would suggest more than the study found.

*Figure: The airway of the public sample scan in blue, seen from the side through faint bone. The airway in this sample scan, seen from the side. Sample scan "CBCT-MR Head (DZ-CBCT)", 3D Slicer sample data, donated for use without restrictions. Screenshot from Jaw Viewer.*

## Does volume differ between men and women?

In that sample, not in volume. The study found sex-related differences in hypopharynx length but not in volume, with a longer hypopharynx in males.[1] A shape analysis of the landmarks also separated the sexes: males tended towards longer, straighter airways, females towards an inverted triangle seen from the front.[1]

So two airways can hold a similar volume and still be shaped differently. A single volume hides length, width and where the narrow parts sit, which is why a volume alone says little about the shape behind it. How the narrowest slice is found is covered in [airway volume on CBCT and the narrowest cross-section](https://jawviewer.com/blog/airway-volume-cbct-what-it-means.md).

## How does the method change the number?

The same scan can give different volumes depending on the program. In a 2010 study, 30 CBCT scans were measured for oropharynx and nasal passage volume in three DICOM viewers and compared with a manual outlining program. Repeat measurements after 2 weeks were highly reliable, and results correlated highly with the manual program, but they differed significantly from it, and the viewers were inconsistent with each other. The authors describe high reliability with poor accuracy, which suggests systematic errors.[2]

A reference range built with one program and a volume from another are not measured in the same way. Reference data from the literature is best read as a rough sense of scale, not a yardstick.

> A volume is not a verdict
>
> A larger or smaller volume than a published group does not say whether an airway works well or badly. The studies above describe spread in groups. They do not link a volume to health, breathing or sleep.

## What else moves the airway?

A scan catches one moment. A 2011 systematic review of 46 articles concluded that 3D analysis of the upper airway on CBCT can be accurate and reliable. It also lists obstacles still to be addressed: the breathing phase, the position of the tongue, the shape of the lower jaw and how the anatomical boundaries of the airway are defined.[3]

Each of these shifts the volume without any change in the person. Someone scanned at the end of an in-breath and again after an out-breath could produce two numbers. A tongue resting differently, or a head tilted a little more, changes the outline. The ends of the measured region matter as well, because someone chooses where the airway starts and stops, as the [airway volume article](https://jawviewer.com/blog/airway-volume-cbct-what-it-means.md) explains.

| Source of spread | What the literature says |
| --- | --- |
| Who was measured | Reference data came from 56 young Japanese adults with normal occlusion[1] |
| Sex | Hypopharynx length differed, volume did not, in that sample[1] |
| Program | Three viewers differed significantly from a manual outline and from each other[2] |
| Moment of the scan | Breathing phase and tongue position are open problems[3] |
| Where the airway ends | Boundary definition is an open problem[3] |

## Measuring your own airway in Jaw Viewer

In Jaw Viewer, the airway tool reports a volume and a narrowest cross-section for the region it outlines, and the [airway and sinuses guide](https://jawviewer.com/guide/airway-and-sinuses.md) shows how to check that region in the slices. Your result describes your scan, outlined this way, on that day. It is not a statement about whether the airway is within a range.

If you want context for a reading, compare like with like: the same scan outlined twice with different borders shows how much the number moves on its own. Questions about breathing or sleep belong with a clinician, because a volume does not settle them. The sinuses raise the same questions about spread, which [maxillary sinus volume and the range reported in studies](https://jawviewer.com/blog/maxillary-sinus-volume-normal-range.md) goes through. For how much a millimetre reading can be trusted at all, read [how accurate CBCT measurements are](https://jawviewer.com/blog/how-accurate-are-cbct-measurements.md).

This is general information, not medical advice. Jaw Viewer is not a medical device. Talk to your surgeon, orthodontist or radiologist about your own case.

## Questions and answers

### Is there a normal upper airway volume on CBCT?

Studies publish reference data for one group, such as 56 young Japanese adults with normal occlusion. The numbers depend on the group and on how the airway was outlined, so they are not a pass or fail line.

### Do men and women have different airway volumes?

In a 2023 study of 56 young Japanese adults, hypopharynx length differed by sex but volume did not. One small group of one age and population does not settle the question for others.

### Why can two programs give different airway volumes for the same scan?

They outline the air differently. In a 2010 study of 30 scans, three viewers were repeatable but differed significantly from a manual outline and from each other.

### Can I compare my airway volume with a published average?

Only loosely. The published group, the airway region and the program all need to match yours, and a breathing phase or tongue position at the moment of the scan also changes the shape.

## Sources

1. Tanikawa C, Oka A, Shiraishi Y et al. (2023). Sex differences in airway volume and 3-dimensional shape in Japanese adults. Sci Rep, vol. 13, pp. 13937. https://doi.org/10.1038/s41598-023-41263-6 56 young Japanese adults with normal occlusion, picked from 1000 patients; oropharynx and hypopharynx only.
2. Guijarro-Martínez R, Swennen GR (2011). Cone-beam computerized tomography imaging and analysis of the upper airway: a systematic review of the literature. Int J Oral Maxillofac Surg, vol. 40, pp. 1227-37. https://doi.org/10.1016/j.ijom.2011.06.017 46 articles included out of 382 screened.
3. El H, Palomo JM (2010). Measuring the airway in 3 dimensions: a reliability and accuracy study. Am J Orthod Dentofacial Orthop, vol. 137(4 Suppl), pp. S50.e1-9. https://doi.org/10.1016/j.ajodo.2010.01.014 30 CBCT scans, three DICOM viewers compared with a manual outlining program.

---

Jaw Viewer (https://jawviewer.com). Page index for AI tools: https://jawviewer.com/llms.txt. Not a medical device.